How to upgrade the NetAppĀ code and perform a NetApp controller fail over step by step.
Few things you will need to considerĀ before you are ready to update the code and performing fail over to reduce downtime during the NetAppĀ code upgrade.
Make sure that all the servers connections are redundant and you have access to the service processors
- Update the dicks firmware ( No down time required )
- Update the BMC firmware ( No down time required )
- Update the OnTap software ( requires failover to the other controller )
The code can be uploaded to the NetApp by using FTP . you can useĀ software called “Wing FTP ” to host FTPĀ connection. I have added link below. you can download it free of cost
https://www.wftpserver.com/
Disk Firmware updatesĀ
You can login to the Cluster IP of the NetApp to copy the disk firmware.
1. login and set the privileged levelĀ
test_san::>
set advanced
Warning: These advanced commands are potentially dangerous; use them only when directed to do so by NetApp personnel.
Do you want to continue? {y|n}: y
2. turn off the automatic failoverĀ
test_san::*>
storage failover modify -node * -auto-giveback false
Warning: Disabling auto-giveback under cluster HA configuration will prevent the management cluster services from automatically going
online under alternating-failure scenarios. Do you want to disable auto-giveback? {y|n}:
y
2 entries were modified.
3. download the software code by specifying the host which is runningĀ an http server:
test_san::*>
96P5_q_image.tgz system node image update -node * -package http://x.x.x.x:8080/96P5_q_image.tgz -setdefault true -replace-package true
Warning: The recommended best-practice is to use the automated non-disruptive update procedure if you are attempting an upgrade or a
minor version downgrade. Refer to the Clustered Data ONTAP Upgrade and Revert/Downgrade Guide for details.
Do you want to continue? {y|n}
: y
Software update started on node test_san1. Updating image2 with package http://…/96P5_q_image.tgz.
Downloading package. This may take up to 10 minutes.
3% downloaded
6% downloaded
4.Ā Once the upload is complete you will see the following message
Boot recovery files installed on recovery partition
Installation complete. image2 updated on node test_san-02.
After a clean shutdown, image2 will be set as the default boot image on node
test_san- 02.
2 entries were acted on.
At this point dynamic fail over is set to false and now we can check what interfaces needs to be re-homed